Hand Held Thermometers
TCA TC308K Digital Thermometer

LIT 1515
- Thermometer
- Auto power off
- Range Type K input –50 to 1300 °C
- Accuracy ±0.3 % + 1 °C
- Resolution 0.1 °C to 199.9 °C then 1 °C
- Supplied in rubber boot with Teflon bead probe
- Recalibration / offset screw on face
- Minimum / maximum function
- Mini plug protected in top panel
Center 301 Digital Thermometer

TC301
- Type K Dual Input T1—T2 ( Mini Plugs )
- Auto Power Off
- Range Type K Input—200 to 1370 °C
- Accuracy +/- 0.3 % + 1°C
- Resolution 0.1 °C
- Minimum / Maximum / Average Function
- Recalibration Screw
- Supplied in Carry Case with 2 x Bead Probes
Center 305 Data Logger Thermometer

LIT 1502
- 16,000 record data logger
- RS-232 or USB interface
- Triple display
- Clock function
- Auto power off
- Range Type K input –200 to 1370 °C
- Accuracy ±0.3 % + 1 °C
- Resolution 0.1 °C
- Carry case with Teflon bead probes
Non Contact Infrared Thermometers

LIT 1981
Quickly and easily take surface temperatures without contact.
- Measuring range –50 to 900 °C
- Distance to spot size 12:1
- Emissivity adjustable 0.1 to 1.0
- Accuracy ±1.5 °C or 1.5%
- Max / min / average functions
TCP300 – Dostmann P300 Thermistor Thermometer
- Single NTC thermistor input
- Integral sensor, not replaceable
- Single LCD display with backlight
- Range –40.0 to 200.0 °C
- Auto power off
- 0.1 °C resolution
- Accuracy ±0.5 °C (0–100 °C), otherwise ±1.5 °C
- Max / min / hold function
TCP400 Hand Held Thermometer

LIT 1981
- PT100 4-wire input
- Range –99.9 to +850 °C
- System accuracy ±0.3 °C
- Resolution 0.1 °C
- Memory for 19 spot measurements
- Average / hold / min / max
TCP700 – Dostmann P700 Single Input Thermometer

- Multi-type sensor input RTD & thermocouple
- Single LCD display
- RTD range –200 to 850 °C
- 0.1 °C resolution
- Max / min / average / hold
- Sensor not included
TCP705 – Dostmann P705 Dual Input Thermometer
- Dual LCD display
- RTD range –200 to 850 °C
- 0.1 °C resolution
- Max / min / average / hold
- Sensors not included
TCP710 – Dostmann P710 Single Input Thermometer
- K, J, L, N & T thermocouple input
- Auto power off
- 0.1 °C resolution
- Max / min / average / hold
- Sensor not included
TCP750 – Dostmann P750 Single Input Thermometer
- High accuracy reference system
- Multi-sensor input
- 0.01 °C resolution
- Max / min / average / hold
- Sensor not included
TCP755 – Dostmann P755 Dual Input Thermometer
- Dual LCD display
- High accuracy reference
- 0.01 °C resolution
- Max / min / average / hold
- Sensor not included
TCP750PT – Dostmann P750PT Single Input Thermometer
- PT100 4-wire input
- High accuracy reference
- 0.01 °C resolution
- Sensor not included
TCP755PT – Dostmann P755PT Dual Input Thermometer
- PT100 4-wire input
- Dual LCD display
- High accuracy reference
- Sensor not included
TCP755LOG – Dostmann P755LOG Dual Input Data Logger
- 6000 measurement logger
- Dual LCD display
- High accuracy reference
- Sensor not included
TCP795 – Dostmann High Precision Reference Logger
- Extreme accuracy system
- 0.001 °C resolution
- RTD input
- Sensor not included
TCV315RTD – Dostmann High Precision RTD with Integrated Display
- PT100 sensor
- Accuracy ±0.05 °C
- Calibration certificate included
- Auto-off function
TC305K Digital Handheld Thermometer SD 345

SD 345
- Type K input
- Single probe
- Range –50 to 1300 °C
Hand Probes

LIT 1359
- Air probe
- Immersion probe
- Surface probe
- Stab probe